Low temperature hydrogen peroxide plasma sterilizer

Low temperature hydrogen peroxide plasma sterilizer

Low temperature hydrogen peroxide plasma sterilizer LB-10LHPS

Low temperature hydrogen peroxide plasma sterilizer LB-10LHPS is a PLC controlled unit. Door can be handled manually. It provides multiple security functions such as alarm for temperature, voltage, pressure control and door finger protection function. 7-inch liquid crystal touch screen displays information regarding running status.

Volume 60 ml
Chamber size (L x W x H) 610 x 350 x 320 mm
Outline dimension (L x W x H) 720 x 630 x 1510 mm
Operating height ≤ 1600 mm
Category Class II medical devices
Sterilizing temperature 50 ℃ ± 5 ℃
Hydrogen peroxide sterilization concentration 60 %
Sterilization time 45 min ± 3 min
Sterilizing chamber material #304 anticorrosive stainless steel or aluminium ( thickness ≥ 8 mm )
Outer box material Carbon steel baking powder and fiberglass
Material of electrode net Aluminium alloy material 5052 ( thickness ≥ 2 mm)
Sealing door material Aluminium alloy material 5052 ( thickness ≥ 15 mm )
Main body insulation material Rubber and plastic sponge ( ≥ 20 mm )
Program system Procedures: reinforcement cycle ( ≤ 50 minutes ) and fast loop( ≤ 30 minutes )
U disk storage capacity ≥ 8 G
Vacuum speed 5 minutes / 50 pa
Air filtration accuracy ≤ 0.2 μm
Heating mode Electrical heating
Door opening mode Manual
Door finger protection function Right handed
Electromagnetic compatibility testing Self – priming injection
Stop caster Present
High temperature alarm system Present
Voltage Present
Power AC 220 V / 50 Hz


AC 380 V / 50 Hz

Plasma power supply 2.6 kW
Gross weight ≤ 900 W
  • Liquid crystal touch screen (displays temperature, pressure, sterilization time, PLC circuit diagram, cycle mode, process phase, alarm information and provide actual interface photos)
  • More humanized operation height (reduced to height of female personnel)
  • High quality thermal conductive sterilizing chamber material
  • Sterilizing chamber material ensures 100 % gaseous state hydrogen peroxide
  • Large loading capacity
  • Preheating time ≤ 30 minutes (increases rate of heating)
  • Insulated main body (low thermal conductivity, fire resistance, anti-aging ability, environmental protection)
  • Micro-printer print out every minute of data of the entire sterilization process (print records: program name, sterilization date, sterilizing pot number, sterilization start end time, sterilization process pressure and temperature change data, phase time and end state information)
  • U disc stores records ≥ 100 ten thousand sterilization data (program sequence number, sterilization date, sterilizing pot number, beginning end time of sterilization, pressure, temperature, stage time and end state of sterilization process)
  • Pressure sensor automatically detects and maintains pressure inside the cavity
  • Temperature sensor automatically detects and maintains temperature inside the cavity
  • Pumping control valve (controls evacuation with high vacuum flapper solenoid valve)
  • Oil mist filter captures oil mist and pump back (reducing fuel consumption)
  • Two meter to four meter sterilization effect
  • Explosion-proof and flame-retardant heating system
  • Multiple protective functions (overvoltage and over temperature protection, door finger protection function and errors displayed on LCD screen)

Used to sterilize the devices (mainly medical instruments) that are thermo labile or would be damaged by moisture of steam sterilization.


Low temperature hydrogen peroxide plasma sterilizer LB-11LHPS

Low temperature hydrogen peroxide plasma sterilizer LB-11LHPS is a PLC controlled unit. Door can be handled manually. It provides multiple security functions such as alarm for temperature, voltage, pressure control and door finger protection function. 7-inch liquid crystal touch screen displays information regarding running status.

Volume 100 ml
Chamber size (L x W x H) 700 x 430 x 360 mm
Outline dimension (L x W x H) 1000 x 800 x 1600 mm
Operating height ≤ 1600 mm
Category Class II medical devices
Sterilizing temperature 50 ℃ ± 5 ℃
Hydrogen peroxide sterilization concentration 60 %
Sterilization time 45 min ± 3 min
Sterilizing chamber material #304 anticorrosive stainless steel or aluminium ( thickness ≥ 8 mm )
Outer box material Carbon steel baking powder and fiberglass
Material of electrode net Aluminium alloy material 5052 ( thickness ≥ 2 mm)
Sealing door material Aluminium alloy material 5052 ( thickness ≥ 15 mm )
Main body insulation material Rubber and plastic sponge ( ≥ 20 mm )
Program system Procedures: reinforcement cycle ( ≤ 50 minutes ) and fast loop( ≤ 30 minutes )
U disk storage capacity ≥ 8 G
Vacuum speed 5 minutes / 50 pa
Air filtration accuracy ≤ 0.2 μm
Heating mode Electrical heating
Door opening mode Manual
Door finger protection function Right handed
Electromagnetic compatibility testing Self – priming injection
Stop caster Present
High temperature alarm system Present
Voltage Present
Power AC 220 V / 50 Hz


AC 380 V / 50 Hz

Plasma power supply 3.8 kW
Gross weight ≤ 900 W
  • Liquid crystal touch screen (displays temperature, pressure, sterilization time, PLC circuit diagram, cycle mode, process phase, alarm information and provide actual interface photos)
  • More humanized operation height (reduced to height of female personnel)
  • High quality thermal conductive sterilizing chamber material
  • Sterilizing chamber material ensures 100 % gaseous state hydrogen peroxide
  • Large loading capacity
  • Preheating time ≤ 30 minutes (increases rate of heating)
  • Insulated main body (low thermal conductivity, fire resistance, anti-aging ability, environmental protection)
  • Micro-printer print out every minute of data of the entire sterilization process (print records: program name, sterilization date, sterilizing pot number, sterilization start end time, sterilization process pressure and temperature change data, phase time and end state information)
  • U disc stores records ≥ 100 ten thousand sterilization data (program sequence number, sterilization date, sterilizing pot number, beginning end time of sterilization, pressure, temperature, stage time and end state of sterilization process)
  • Pressure sensor automatically detects and maintains pressure inside the cavity
  • Temperature sensor automatically detects and maintains temperature inside the cavity
  • Pumping control valve (controls evacuation with high vacuum flapper solenoid valve)
  • Oil mist filter captures oil mist and pump back (reducing fuel consumption)
  • Two meter to four meter sterilization effect
  • Explosion-proof and flame-retardant heating system
  • Multiple protective functions (overvoltage and over temperature protection, door finger protection function and errors displayed on LCD screen)

Used to sterilize the devices (mainly medical instruments) that are thermo labile or would be damaged by moisture of steam sterilization.


Low temperature hydrogen peroxide plasma sterilizer LB-12LHPS

Low temperature hydrogen peroxide plasma sterilizer LB-12LHPS is a PLC controlled unit. Door can be handled manually. It provides multiple security functions such as alarm for temperature, voltage, pressure control and door finger protection function. 7-inch liquid crystal touch screen displays information regarding running status.

Volume 130 ml
Chamber size (L x W x H) 750 x 450 x 400 mm
Outline dimension (L x W x H) 1040 x 800 x 1600 mm
Operating height ≤ 1600 mm
Category Class II medical devices
Sterilizing temperature 50 ℃ ± 5 ℃
Hydrogen peroxide sterilization concentration 60 %
Sterilization time 45 min ± 3 min
Sterilizing chamber material #304 anticorrosive stainless steel or aluminium ( thickness ≥ 8 mm )
Outer box material Carbon steel baking powder and fiberglass
Material of electrode net Aluminium alloy material 5052 ( thickness ≥ 2 mm)
Sealing door material Aluminium alloy material 5052 ( thickness ≥ 15 mm )
Main body insulation material Rubber and plastic sponge ( ≥ 20 mm )
Program system Procedures: reinforcement cycle ( ≤ 50 minutes ) and fast loop( ≤ 30 minutes )
U disk storage capacity ≥ 8 G
Vacuum speed 5 minutes / 50 pa
Air filtration accuracy ≤ 0.2 μm
Heating mode Electrical heating
Door opening mode Manual
Door finger protection function Right handed
Electromagnetic compatibility testing Self – priming injection
Stop caster Present
High temperature alarm system Present
Voltage Present
Power AC 220 V / 50 Hz


AC 380 V / 50 Hz

Plasma power supply 4.2 kW
Gross weight ≤ 900 W
  • Liquid crystal touch screen (displays temperature, pressure, sterilization time, PLC circuit diagram, cycle mode, process phase, alarm information and provide actual interface photos)
  • More humanized operation height (reduced to height of female personnel)
  • High quality thermal conductive sterilizing chamber material
  • Sterilizing chamber material ensures 100 % gaseous state hydrogen peroxide
  • Large loading capacity
  • Preheating time ≤ 30 minutes (increases rate of heating)
  • Insulated main body (low thermal conductivity, fire resistance, anti-aging ability, environmental protection)
  • Micro-printer print out every minute of data of the entire sterilization process (print records: program name, sterilization date, sterilizing pot number, sterilization start end time, sterilization process pressure and temperature change data, phase time and end state information)
  • U disc stores records ≥ 100 ten thousand sterilization data (program sequence number, sterilization date, sterilizing pot number, beginning end time of sterilization, pressure, temperature, stage time and end state of sterilization process)
  • Pressure sensor automatically detects and maintains pressure inside the cavity
  • Temperature sensor automatically detects and maintains temperature inside the cavity
  • Pumping control valve (controls evacuation with high vacuum flapper solenoid valve)
  • Oil mist filter captures oil mist and pump back (reducing fuel consumption)
  • Two meter to four meter sterilization effect
  • Explosion-proof and flame-retardant heating system
  • Multiple protective functions (overvoltage and over temperature protection, door finger protection function and errors displayed on LCD screen)

Used to sterilize the devices (mainly medical instruments) that are thermo labile or would be damaged by moisture of steam sterilization.


Low temperature hydrogen peroxide plasma sterilizer LB-13LHPS

Low temperature hydrogen peroxide plasma sterilizer LB-13LHPS is a PLC controlled unit. Door can be handled manually. It provides multiple security functions such as alarm for temperature, voltage, pressure control and door finger protection function. 7-inch liquid crystal touch screen displays information regarding running status.

Volume 190 ml
Chamber size (L x W x H) 820 x 510 x 460 mm
Outline dimension (L x W x H) 1120 x 830 x 1600 mm
Operating height ≤ 1600 mm
Category Class II medical devices
Sterilizing temperature 50 ℃ ± 5 ℃
Hydrogen peroxide sterilization concentration 60 %
Sterilization time 45 min ± 3 min
Sterilizing chamber material #304 anticorrosive stainless steel or aluminium ( thickness ≥ 8 mm )
Outer box material Carbon steel baking powder and fiberglass
Material of electrode net Aluminium alloy material 5052 ( thickness ≥ 2 mm)
Sealing door material Aluminium alloy material 5052 ( thickness ≥ 15 mm )
Main body insulation material Rubber and plastic sponge ( ≥ 20 mm )
Program system Procedures: reinforcement cycle ( ≤ 50 minutes ) and fast loop( ≤ 30 minutes )
U disk storage capacity ≥ 8 G
Vacuum speed 5 minutes / 50 pa
Air filtration accuracy ≤ 0.2 μm
Heating mode Electrical heating
Door opening mode Manual
Door finger protection function Right handed
Electromagnetic compatibility testing Self – priming injection
Stop caster Present
High temperature alarm system Present
Voltage Present
Power AC 220 V / 50 Hz


AC 380 V / 50 Hz

Plasma power supply 5.0 kW
Gross weight ≤ 900 W
  • Liquid crystal touch screen (displays temperature, pressure, sterilization time, PLC circuit diagram, cycle mode, process phase, alarm information and provide actual interface photos)
  • More humanized operation height (reduced to height of female personnel)
  • High quality thermal conductive sterilizing chamber material
  • Sterilizing chamber material ensures 100 % gaseous state hydrogen peroxide
  • Large loading capacity
  • Preheating time ≤ 30 minutes (increases rate of heating)
  • Insulated main body (low thermal conductivity, fire resistance, anti-aging ability, environmental protection)
  • Micro-printer print out every minute of data of the entire sterilization process (print records: program name, sterilization date, sterilizing pot number, sterilization start end time, sterilization process pressure and temperature change data, phase time and end state information)
  • U disc stores records ≥ 100 ten thousand sterilization data (program sequence number, sterilization date, sterilizing pot number, beginning end time of sterilization, pressure, temperature, stage time and end state of sterilization process)
  • Pressure sensor automatically detects and maintains pressure inside the cavity
  • Temperature sensor automatically detects and maintains temperature inside the cavity
  • Pumping control valve (controls evacuation with high vacuum flapper solenoid valve)
  • Oil mist filter captures oil mist and pump back (reducing fuel consumption)
  • Two meter to four meter sterilization effect
  • Explosion-proof and flame-retardant heating system
  • Multiple protective functions (overvoltage and over temperature protection, door finger protection function and errors displayed on LCD screen)

Used to sterilize the devices (mainly medical instruments) that are thermo labile or would be damaged by moisture of steam sterilization.


Low temperature hydrogen peroxide plasma sterilizer LB-20LHPS

Low temperature hydrogen peroxide plasma sterilizer LB-20LHPS is a PLC controlled unit. Door can be handled by automatic electrical opening for safety. Automatic electrical opening provides additional function of biological culture indicator. It provides multiple security functions such as alarm for temperature, voltage, pressure control and door finger protection function. 7-inch liquid crystal touch screen displays information regarding running status.

Volume 100 ml
Chamber size (L x W x H) 700 x 430 x 360 mm
Outline dimension (L x W x H) 1070 x 810 x 1600 mm
Operating height ≤ 1600 mm
Category Class II medical devices
Installation environment 5 ℃ ~ 45 ℃
Sterilizing temperature 50 ℃
Hydrogen peroxide sterilization concentration 60 %
Sterilization time 45 min ~ 50 min
Sterilizing chamber material #304 anticorrosive stainless steel or aluminium ( thickness ≥ 8 mm )
Outer box material Carbon steel baking powder and fiberglass
Material of electrode net Aluminium alloy material 5052 ( thickness ≥ 2 mm)
Sealing door material Aluminium alloy material 5052 ( thickness ≥ 15 mm )
Main body insulation material Rubber and plastic sponge ( ≥ 20 mm )
Program system Procedures: reinforcement cycle ( ≤ 50 minutes ) and fast loop( ≤ 30 minutes )
U disk storage capacity ≥ 8 G
Maximum pressure resistance 10 pa
Biological indicator culture Present
Vacuum speed 5 minutes / 50 pa
Air filtration accuracy ≤ 0.2 μm
Heating mode Electrical heating
Door opening mode Electric push rod drive
Door finger protection function Lifting type
Hydrogen peroxide injection mode Door barrier switch function
Electromagnetic compatibility testing Self – priming injection
Stop caster Present
High temperature alarm system Present
Voltage Present
Power AC 220 V / 50 Hz


AC 380 V / 50 Hz

Plasma power supply 3.95 kW
Gross weight ≤ 900 W
  • Liquid crystal touch screen (displays temperature, pressure, sterilization time, PLC circuit diagram, cycle mode, process phase, alarm information and provide actual interface photos)
  • More humanized operation height (reduced to height of female personnel)
  • High quality thermal conductive sterilizing chamber material
  • Sterilizing chamber material ensures 100 % gaseous state hydrogen peroxide
  • Large loading capacity
  • Preheating time ≤ 30 minutes (increases rate of heating)
  • Insulated main body (low thermal conductivity, fire resistance, anti-aging ability, environmental protection)
  • Micro-printer print out every minute of data of the entire sterilization process (print records: program name, sterilization date, sterilizing pot number, sterilization start end time, sterilization process pressure and temperature change data, phase time and end state information)
  • U disc stores records ≥ 100 ten thousand sterilization data (program sequence number, sterilization date, sterilizing pot number, beginning end time of sterilization, pressure, temperature, stage time and end state of sterilization process)
  • Pressure sensor automatically detects and maintains pressure inside the cavity
  • Temperature sensor automatically detects and maintains temperature inside the cavity
  • Pumping control valve (controls evacuation with high vacuum flapper solenoid valve)
  • Oil mist filter captures oil mist and pump back (reducing fuel consumption)
  • Two meter to four meter sterilization effect
  • Explosion-proof and flame-retardant heating system
  • Multiple protective functions (overvoltage and over temperature protection, door finger protection function and errors displayed on LCD screen)

Used to sterilize the devices (mainly medical instruments) that are thermo labile or would be damaged by moisture of steam sterilization.


Low temperature hydrogen peroxide plasma sterilizer LB-21LHPS

Low temperature hydrogen peroxide plasma sterilizer LB-21LHPS is a PLC controlled unit. Door can be handled by automatic electrical opening for safety. Automatic electrical opening provides additional function of biological culture indicator. It provides multiple security functions such as alarm for temperature, voltage, pressure control and door finger protection function. 7-inch liquid crystal touch screen displays information regarding running status.

Volume 130 ml
Chamber size (L x W x H) 750 x 450 x 400 mm
Outline dimension (L x W x H) 1040 x 800 x 1780 mm
Operating height ≤ 1600 mm
Category Class II medical devices
Installation environment 5 ℃ ~ 45 ℃
Sterilizing temperature 50 ℃
Hydrogen peroxide sterilization concentration 60 %
Sterilization time 45 min ~ 50 min
Sterilizing chamber material #304 anticorrosive stainless steel or aluminium ( thickness ≥ 8 mm )
Outer box material Carbon steel baking powder and fiberglass
Material of electrode net Aluminium alloy material 5052 ( thickness ≥ 2 mm)
Sealing door material Aluminium alloy material 5052 ( thickness ≥ 15 mm )
Main body insulation material Rubber and plastic sponge ( ≥ 20 mm )
Program system Procedures: reinforcement cycle ( ≤ 50 minutes ) and fast loop( ≤ 30 minutes )
U disk storage capacity ≥ 8 G
Maximum pressure resistance 10 pa
Biological indicator culture Present
Vacuum speed 5 minutes / 50 pa
Air filtration accuracy ≤ 0.2 μm
Heating mode Electrical heating
Door opening mode Electric push rod drive
Door finger protection function Lifting type
Hydrogen peroxide injection mode Door barrier switch function
Electromagnetic compatibility testing Self – priming injection
Stop caster Present
High temperature alarm system Present
Voltage Present
Power AC 220 V / 50 Hz


AC 380 V / 50 Hz

Plasma power supply 4.35 kW
Gross weight ≤ 900 W
  • Liquid crystal touch screen (displays temperature, pressure, sterilization time, PLC circuit diagram, cycle mode, process phase, alarm information and provide actual interface photos)
  • More humanized operation height (reduced to height of female personnel)
  • High quality thermal conductive sterilizing chamber material
  • Sterilizing chamber material ensures 100 % gaseous state hydrogen peroxide
  • Large loading capacity
  • Preheating time ≤ 30 minutes (increases rate of heating)
  • Insulated main body (low thermal conductivity, fire resistance, anti-aging ability, environmental protection)
  • Micro-printer print out every minute of data of the entire sterilization process (print records: program name, sterilization date, sterilizing pot number, sterilization start end time, sterilization process pressure and temperature change data, phase time and end state information)
  • U disc stores records ≥ 100 ten thousand sterilization data (program sequence number, sterilization date, sterilizing pot number, beginning end time of sterilization, pressure, temperature, stage time and end state of sterilization process)
  • Pressure sensor automatically detects and maintains pressure inside the cavity
  • Temperature sensor automatically detects and maintains temperature inside the cavity
  • Pumping control valve (controls evacuation with high vacuum flapper solenoid valve)
  • Oil mist filter captures oil mist and pump back (reducing fuel consumption)
  • Two meter to four meter sterilization effect
  • Explosion-proof and flame-retardant heating system
  • Multiple protective functions (overvoltage and over temperature protection, door finger protection function and errors displayed on LCD screen)

Used to sterilize the devices (mainly medical instruments) that are thermo labile or would be damaged by moisture of steam sterilization.


Low temperature hydrogen peroxide plasma sterilizer LB-22LHPS

Low temperature hydrogen peroxide plasma sterilizer LB-22LHPS is a PLC controlled unit. Door can be handled by automatic electrical opening for safety. Automatic electrical opening provides additional function of biological culture indicator. It provides multiple security functions such as alarm for temperature, voltage, pressure control and door finger protection function. 7-inch liquid crystal touch screen displays information regarding running status.

Volume 190 ml
Chamber size (L x W x H) 820 x 510 x 460 mm
Outline dimension (L x W x H) 1070 x 810 x 1780 mm
Operating height ≤ 1600 mm
Category Class II medical devices
Installation environment 5 ℃ ~ 45 ℃
Sterilizing temperature 50 ℃
Hydrogen peroxide sterilization concentration 60 %
Sterilization time 45 min ~ 50 min
Sterilizing chamber material #304 anticorrosive stainless steel or aluminium ( thickness ≥ 8 mm )
Outer box material Carbon steel baking powder and fiberglass
Material of electrode net Aluminium alloy material 5052 ( thickness ≥ 2 mm)
Sealing door material Aluminium alloy material 5052 ( thickness ≥ 15 mm )
Main body insulation material Rubber and plastic sponge ( ≥ 20 mm )
Program system Procedures: reinforcement cycle ( ≤ 50 minutes ) and fast loop( ≤ 30 minutes )
U disk storage capacity ≥ 8 G
Maximum pressure resistance 10 pa
Biological indicator culture Present
Vacuum speed 5 minutes / 50 pa
Air filtration accuracy ≤ 0.2 μm
Heating mode Electrical heating
Door opening mode Electric push rod drive
Door finger protection function Lifting type
Hydrogen peroxide injection mode Door barrier switch function
Electromagnetic compatibility testing Self – priming injection
Stop caster Present
High temperature alarm system Present
Voltage Present
Power AC 220 V / 50 Hz


AC 380 V / 50 Hz

Plasma power supply 5.15 kW
Gross weight ≤ 900 W
  • Liquid crystal touch screen (displays temperature, pressure, sterilization time, PLC circuit diagram, cycle mode, process phase, alarm information and provide actual interface photos)
  • More humanized operation height (reduced to height of female personnel)
  • High quality thermal conductive sterilizing chamber material
  • Sterilizing chamber material ensures 100 % gaseous state hydrogen peroxide
  • Large loading capacity
  • Preheating time ≤ 30 minutes (increases rate of heating)
  • Insulated main body (low thermal conductivity, fire resistance, anti-aging ability, environmental protection)
  • Micro-printer print out every minute of data of the entire sterilization process (print records: program name, sterilization date, sterilizing pot number, sterilization start end time, sterilization process pressure and temperature change data, phase time and end state information)
  • U disc stores records ≥ 100 ten thousand sterilization data (program sequence number, sterilization date, sterilizing pot number, beginning end time of sterilization, pressure, temperature, stage time and end state of sterilization process)
  • Pressure sensor automatically detects and maintains pressure inside the cavity
  • Temperature sensor automatically detects and maintains temperature inside the cavity
  • Pumping control valve (controls evacuation with high vacuum flapper solenoid valve)
  • Oil mist filter captures oil mist and pump back (reducing fuel consumption)
  • Two meter to four meter sterilization effect
  • Explosion-proof and flame-retardant heating system
  • Multiple protective functions (overvoltage and over temperature protection, door finger protection function and errors displayed on LCD screen)

Used to sterilize the devices (mainly medical instruments) that are thermo labile or would be damaged by moisture of steam sterilization.