{"id":3226,"date":"2021-05-03T22:15:53","date_gmt":"2021-05-03T22:15:53","guid":{"rendered":"https:\/\/rehmantech.net\/demo\/bsscientifics\/?p=3226"},"modified":"2021-05-07T13:10:26","modified_gmt":"2021-05-07T13:10:26","slug":"automatic-biochemistry-analyzer-lb-10aba","status":"publish","type":"post","link":"https:\/\/rehmantech.net\/demo\/bsscientifics\/laboratory\/automatic-biochemistry-analyzer-lb-10aba\/","title":{"rendered":"Automatic Biochemistry Analyzer LB-10ABA"},"content":{"rendered":"<p>[vc_row][vc_column][vc_cta h2=&#8221;Automatic Biochemistry Analyzer LB-10ABA&#8221; style=&#8221;custom&#8221; add_button=&#8221;right&#8221; btn_title=&#8221;Get Quote&#8221; btn_style=&#8221;outline&#8221; btn_color=&#8221;white&#8221; btn_size=&#8221;lg&#8221; btn_skin=&#8221;light&#8221; btn_scale=&#8221;scale-2&#8243; btn_show_arrow=&#8221;yes&#8221; btn_btn_arrow=&#8221;yes&#8221; css_animation=&#8221;fadeInUpBig&#8221; custom_background=&#8221;#a561a9&#8243; custom_text=&#8221;#ffffff&#8221;][\/vc_cta][\/vc_column][\/vc_row][vc_row css=&#8221;.vc_custom_1619893416459{margin-top: 100px !important;padding-bottom: 100px !important;}&#8221;][vc_column width=&#8221;1\/4&#8243;][vc_single_image image=&#8221;3227&#8243; img_size=&#8221;full&#8221; alignment=&#8221;center&#8221; lightbox=&#8221;yes&#8221; label=&#8221;&#8221;][\/vc_column][vc_column width=&#8221;3\/4&#8243;][vc_column_text]<\/p>\n<h2 class=\"product-title\" title=\"Automatic biochemistry analyzer LB-10ABA\">Automatic Biochemistry Analyzer LB-10ABA<\/h2>\n<p title=\"Automatic biochemistry analyzer LB-10ABA is a unit with advanced, highly sensitive test technology. Features high accuracy diluter, advanced seal and connecting technology to provide accurate sampling. Two separate reagent chambers with independent refrigerators. Internal and external Nano treated probe effectively reduce probe residual and carry over.\">Automatic biochemistry analyzer LB-10ABA is a unit with advanced, highly sensitive test technology. Features high accuracy diluter, advanced seal and connecting technology to provide accurate sampling. Two separate reagent chambers with independent refrigerators. Internal and external Nano treated probe effectively reduce probe residual and carry over<\/p>\n<p>[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_tta_tabs style=&#8221;modern&#8221; color=&#8221;white&#8221; alignment=&#8221;center&#8221; active_section=&#8221;1&#8243; css_animation=&#8221;fadeInUpBig&#8221; css=&#8221;.vc_custom_1619955735016{background-color: #ffffff !important;}&#8221;][vc_tta_section title=&#8221;Specification&#8221; tab_id=&#8221;1619955253898-53ec73a7-d134&#8243;][vc_column_text]<\/p>\n<table class=\"table table-striped table-bordered displayshow1\">\n<tbody>\n<tr class=\"trset1\">\n<td title=\"Throughput-includes ISE\"><strong>Throughput-includes ISE<\/strong><\/td>\n<td title=\"960 test\/ hr.\">960 test\/ hr.<\/td>\n<\/tr>\n<tr class=\"trset1\">\n<td title=\"Throughput-includes biochemical test only\"><strong>Throughput-includes biochemical test only<\/strong><\/td>\n<td title=\"800 test\/ hr.\">800 test\/ hr.<\/td>\n<\/tr>\n<tr class=\"trset1\">\n<td title=\"Sample capacity\"><strong>Sample capacity<\/strong><\/td>\n<td title=\"2 x 100 primary tube or micro serum cup\">2 x 100 primary tube or micro serum cup<\/td>\n<\/tr>\n<tr class=\"trset1\">\n<td title=\"Sample volume\"><strong>Sample volume<\/strong><\/td>\n<td title=\"1.0 \u00b5L to 100 \u00b5L in .01 \u00b5L\/ step\">1.0 \u00b5L to 100 \u00b5L in .01 \u00b5L\/ step<\/td>\n<\/tr>\n<tr class=\"trset1\">\n<td title=\"Reagent volume\"><strong>Reagent volume<\/strong><\/td>\n<td title=\"1 \u00b5L to 500 \u00b5L in 0.1\/ step\">1 \u00b5L to 500 \u00b5L in 0.1\/ step<\/td>\n<\/tr>\n<tr class=\"trset1\">\n<td title=\"Reagent tray\"><strong>Reagent tray<\/strong><\/td>\n<td title=\"2 reagent strays, barcode scanner available (on request)\">2 reagent strays, barcode scanner available (on request)<\/td>\n<\/tr>\n<tr class=\"trset1\">\n<td title=\"Reagent refrigerator\"><strong>Reagent refrigerator<\/strong><\/td>\n<td title=\"2 \u00b0C to 8 \u00b0C, 24 hrs. available\">2 \u00b0C to 8 \u00b0C, 24 hrs. available<\/td>\n<\/tr>\n<tr class=\"trset1\">\n<td title=\"Reading cuvette\"><strong>Reading cuvette<\/strong><\/td>\n<td title=\"160 cuvettes\">160 cuvettes<\/td>\n<\/tr>\n<tr class=\"trset1\">\n<td title=\"Reaction volume\"><strong>Reaction volume<\/strong><\/td>\n<td title=\"Minimum 120 \u00b5L\">Minimum 120 \u00b5L<\/td>\n<\/tr>\n<tr class=\"trset1\">\n<td title=\"Reaction disc temperature\"><strong>Reaction disc temperature<\/strong><\/td>\n<td title=\"37 \u00b0C \u00b1 0.1 \u00b0C\">37 \u00b0C \u00b1 0.1 \u00b0C<\/td>\n<\/tr>\n<tr class=\"trset1\">\n<td title=\"Carry- over\"><strong>Carry- over<\/strong><\/td>\n<td title=\"Less than 0.0005%\">Less than 0.0005%<\/td>\n<\/tr>\n<tr class=\"trset1\">\n<td title=\"Wavelength range\"><strong>Wavelength range<\/strong><\/td>\n<td title=\"340 nm to 810 nm\">340 nm to 810 nm<\/td>\n<\/tr>\n<tr class=\"trset1\">\n<td title=\"Power supply\"><strong>Power supply<\/strong><\/td>\n<td style=\"font-family: Rambla, sans-serif !important; letter-spacing: 0px !important; box-sizing: border-box; color: #000000; padding: 8px; line-height: 1.42857; vertical-align: top; border: 1px solid #dddddd; text-align: center;\" title=\"AC 110 V \/ 60 Hz &lt;hr&gt; 220 V \/ 50 Hz\">AC 110 V \/ 60 Hz<\/p>\n<hr \/>\n<p>220 V \/ 50 Hz<\/td>\n<\/tr>\n<tr class=\"trset1\">\n<td title=\"Dimensions\"><strong>Dimensions<\/strong><\/td>\n<td title=\"1200 x 900 x 1100 mm\">1200 x 900 x 1100 mm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;Features&#8221; tab_id=&#8221;1619955253927-f2fa3760-6480&#8243;][vc_column_text]<\/p>\n<ul>\n<li class=\"list_view\">Smart warning and easy to correct function<\/li>\n<li class=\"list_view\">Levey Jennings quality control program at multi-level<\/li>\n<li class=\"list_view\">Reaction curve displaying on line and storing helps results analysis<\/li>\n<li class=\"list_view\">Methods &#8211; Endpoint, kinetic (rate), fixed time, single standard, multi-standard, single wavelength assay, biochromatic, bi-reagent assay, serum blank assay, immunoturbidimetry assay and ISE assay (K\/Na\/Ca\/ Cl\/ PH)<\/li>\n<li class=\"list_view\">Multi report formats and user-self-defined report format is available<\/li>\n<li class=\"list_view\">Powerful software for calculating, banking, multi-analysis, data reviewing, QC and results management<\/li>\n<li class=\"list_view\">Automatic alarm function<\/li>\n<li class=\"list_view\">ISE module (Optional)<\/li>\n<li class=\"list_view\">In ISE module, test various ion items with accurate results<\/li>\n<li class=\"list_view\">Quartz glass cuvette available on request<\/li>\n<li class=\"list_view\"><\/li>\n<\/ul>\n<p>[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;Application&#8221; tab_id=&#8221;1619955295151-d6e97e48-8c44&#8243;][vc_column_text]Used for the analysis of various biological components in fields such as pathology, medical microbiology, and research purposes.[\/vc_column_text][\/vc_tta_section][\/vc_tta_tabs][\/vc_column][\/vc_row]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>[vc_row][vc_column][vc_cta h2=&#8221;Automatic Biochemistry Analyzer LB-10ABA&#8221; style=&#8221;custom&#8221; add_button=&#8221;right&#8221; btn_title=&#8221;Get Quote&#8221; btn_style=&#8221;outline&#8221; btn_color=&#8221;white&#8221; btn_size=&#8221;lg&#8221; btn_skin=&#8221;light&#8221; btn_scale=&#8221;scale-2&#8243; btn_show_arrow=&#8221;yes&#8221; btn_btn_arrow=&#8221;yes&#8221; css_animation=&#8221;fadeInUpBig&#8221; custom_background=&#8221;#a561a9&#8243; custom_text=&#8221;#ffffff&#8221;][\/vc_cta][\/vc_column][\/vc_row][vc_row css=&#8221;.vc_custom_1619893416459{margin-top: 100px !important;padding-bottom: 100px !important;}&#8221;][vc_column width=&#8221;1\/4&#8243;][vc_single_image image=&#8221;3227&#8243; img_size=&#8221;full&#8221; alignment=&#8221;center&#8221; lightbox=&#8221;yes&#8221; label=&#8221;&#8221;][\/vc_column][vc_column width=&#8221;3\/4&#8243;][vc_column_text] Automatic Biochemistry Analyzer LB-10ABA Automatic biochemistry analyzer LB-10ABA is a unit with advanced, highly sensitive test technology. Features high accuracy diluter, advanced seal and [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3227,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[10,2],"tags":[],"class_list":["post-3226","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-lab-equipment","category-laboratory"],"featured_image_src":{"landsacpe":["https:\/\/rehmantech.net\/demo\/bsscientifics\/wp-content\/uploads\/2021\/05\/Automatic-biochemistry-analyzer-LB-10ABA-250x250-1.jpg",250,250,false],"list":["https:\/\/rehmantech.net\/demo\/bsscientifics\/wp-content\/uploads\/2021\/05\/Automatic-biochemistry-analyzer-LB-10ABA-250x250-1.jpg",250,250,false],"medium":["https:\/\/rehmantech.net\/demo\/bsscientifics\/wp-content\/uploads\/2021\/05\/Automatic-biochemistry-analyzer-LB-10ABA-250x250-1.jpg",250,250,false],"full":["https:\/\/rehmantech.net\/demo\/bsscientifics\/wp-content\/uploads\/2021\/05\/Automatic-biochemistry-analyzer-LB-10ABA-250x250-1.jpg",250,250,false]},"_links":{"self":[{"href":"https:\/\/rehmantech.net\/demo\/bsscientifics\/wp-json\/wp\/v2\/posts\/3226","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/rehmantech.net\/demo\/bsscientifics\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/rehmantech.net\/demo\/bsscientifics\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/rehmantech.net\/demo\/bsscientifics\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/rehmantech.net\/demo\/bsscientifics\/wp-json\/wp\/v2\/comments?post=3226"}],"version-history":[{"count":1,"href":"https:\/\/rehmantech.net\/demo\/bsscientifics\/wp-json\/wp\/v2\/posts\/3226\/revisions"}],"predecessor-version":[{"id":3228,"href":"https:\/\/rehmantech.net\/demo\/bsscientifics\/wp-json\/wp\/v2\/posts\/3226\/revisions\/3228"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/rehmantech.net\/demo\/bsscientifics\/wp-json\/wp\/v2\/media\/3227"}],"wp:attachment":[{"href":"https:\/\/rehmantech.net\/demo\/bsscientifics\/wp-json\/wp\/v2\/media?parent=3226"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/rehmantech.net\/demo\/bsscientifics\/wp-json\/wp\/v2\/categories?post=3226"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/rehmantech.net\/demo\/bsscientifics\/wp-json\/wp\/v2\/tags?post=3226"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}