{"id":4458,"date":"2021-06-28T21:30:37","date_gmt":"2021-06-28T16:30:37","guid":{"rendered":"https:\/\/rehmantech.net\/demo\/bsscientifics\/?p=4458"},"modified":"2021-06-28T21:31:37","modified_gmt":"2021-06-28T16:31:37","slug":"86-c-ult-chest-freezer","status":"publish","type":"post","link":"https:\/\/rehmantech.net\/demo\/bsscientifics\/laboratory\/86-c-ult-chest-freezer\/","title":{"rendered":"-86 \u00b0C ULT Chest Freezer"},"content":{"rendered":"<p>[vc_row][vc_column][vc_cta h2=&#8221;-86 \u00b0C ULT Chest Freezer&#8221; style=&#8221;custom&#8221; add_button=&#8221;right&#8221; btn_title=&#8221;Get Quote&#8221; btn_style=&#8221;outline&#8221; btn_color=&#8221;white&#8221; btn_size=&#8221;lg&#8221; btn_skin=&#8221;light&#8221; btn_scale=&#8221;scale-2&#8243; btn_show_arrow=&#8221;yes&#8221; btn_btn_arrow=&#8221;yes&#8221; css_animation=&#8221;fadeInUpBig&#8221; custom_background=&#8221;#a561a9&#8243; custom_text=&#8221;#ffffff&#8221;][\/vc_cta][\/vc_column][\/vc_row][vc_row css=&#8221;.vc_custom_1619893416459{margin-top: 100px !important;padding-bottom: 100px !important;}&#8221;][vc_column][vc_single_image image=&#8221;4459&#8243; img_size=&#8221;full&#8221; alignment=&#8221;center&#8221; lightbox=&#8221;yes&#8221; label=&#8221;&#8221;][vc_column_text]<\/p>\n<h2 class=\"product-title\" style=\"text-align: center;\" title=\"-86 \u00b0C ULT Chest freezer LB-20UCF\">-86 \u00b0C ULT Chest Freezer LB-20UCF<\/h2>\n<p style=\"text-align: center;\" title=\"-86 \u00b0C ULT Chest freezer LB-20UCF is a cold storage horizontal freezer equipped with electronic temperature control. Direct-cooling ensures consistent performance at utmost efficiency for prolonged refrigeration. Storage zone can be suitably organized for optimum space utilization to maximize sample occupancy. Temperature controller renders reliable temperature stability. System alarms include high or low set temperature limits, sensor fail, temperature controller fail and power-off conditions.\">-86 \u00b0C ULT Chest freezer LB-20UCF is a cold storage horizontal freezer equipped with electronic temperature control. Direct-cooling ensures consistent performance at utmost efficiency for prolonged refrigeration. Storage zone can be suitably organized for optimum space utilization to maximize sample occupancy. Temperature controller renders reliable temperature stability. System alarms include high or low set temperature limits, sensor fail, temperature controller fail and power-off conditions.<\/p>\n<p>[\/vc_column_text][vc_tta_tabs style=&#8221;modern&#8221; color=&#8221;white&#8221; alignment=&#8221;center&#8221; active_section=&#8221;1&#8243; css_animation=&#8221;fadeInUpBig&#8221; css=&#8221;.vc_custom_1619955735016{background-color: #ffffff !important;}&#8221;][vc_tta_section title=&#8221;Specification&#8221; tab_id=&#8221;1619955253898-53ec73a7-d134&#8243;][vc_column_text]<\/p>\n<table class=\"table table-striped table-bordered displayshow1\">\n<tbody>\n<tr class=\"trset1\">\n<td title=\"Storage capacity\"><strong>Storage capacity<\/strong><\/td>\n<td title=\"50 L\">50 L<\/td>\n<\/tr>\n<tr class=\"trset1\">\n<td title=\"Baskets\"><strong>Baskets<\/strong><\/td>\n<td title=\"2\">2<\/td>\n<\/tr>\n<tr class=\"trset1\">\n<td title=\"External size\"><strong>External size<\/strong><\/td>\n<td title=\"680 \u00d7 580 \u00d7 935 mm\">680 \u00d7 580 \u00d7 935 mm<\/td>\n<\/tr>\n<tr class=\"trset1\">\n<td title=\"Internal size\"><strong>Internal size<\/strong><\/td>\n<td title=\"480 \u00d7 380 \u00d7 665 mm\">480 \u00d7 380 \u00d7 665 mm<\/td>\n<\/tr>\n<tr class=\"trset1\">\n<td title=\"Temperature range\"><strong>Temperature range<\/strong><\/td>\n<td title=\"-40 \u00b0C to -86 \u00b0C\">-40 \u00b0C to -86 \u00b0C<\/td>\n<\/tr>\n<tr class=\"trset1\">\n<td title=\"Temperature sensor\"><strong>Temperature sensor<\/strong><\/td>\n<td title=\"PTC\">PTC<\/td>\n<\/tr>\n<tr class=\"trset1\">\n<td title=\"Evaporator\"><strong>Evaporator<\/strong><\/td>\n<td title=\"Copper coiled tube\">Copper coiled tube<\/td>\n<\/tr>\n<tr class=\"trset1\">\n<td title=\"Condenser\"><strong>Condenser<\/strong><\/td>\n<td title=\"Tube type\">Tube type<\/td>\n<\/tr>\n<tr class=\"trset1\">\n<td title=\"Compressor\"><strong>Compressor<\/strong><\/td>\n<td title=\"1\">1<\/td>\n<\/tr>\n<tr class=\"trset1\">\n<td title=\"Refrigerant\"><strong>Refrigerant<\/strong><\/td>\n<td title=\"Mixed\">Mixed<\/td>\n<\/tr>\n<tr class=\"trset1\">\n<td title=\"No. of test holes\"><strong>No. of test holes<\/strong><\/td>\n<td title=\"1\">1<\/td>\n<\/tr>\n<tr class=\"trset1\">\n<td title=\"Diameter of test hole\"><strong>Diameter of test hole<\/strong><\/td>\n<td title=\"25 mm\">25 mm<\/td>\n<\/tr>\n<tr class=\"trset1\">\n<td title=\"Noise\"><strong>Noise<\/strong><\/td>\n<td title=\"53 dB\">53 dB<\/td>\n<\/tr>\n<tr class=\"trset1\">\n<td title=\"Power consumption\"><strong>Power consumption<\/strong><\/td>\n<td title=\"3.8 kWh\">3.8 kWh<\/td>\n<\/tr>\n<tr class=\"trset1\">\n<td title=\"Power supply\"><strong>Power supply<\/strong><\/td>\n<td title=\"220 V \/ 50 Hz ; 2.2 A\">220 V \/ 50 Hz ; 2.2 A<\/td>\n<\/tr>\n<tr class=\"trset1\">\n<td title=\"Power\"><strong>Power<\/strong><\/td>\n<td title=\"455 W\">455 W<\/td>\n<\/tr>\n<tr class=\"trset1\">\n<td title=\"Weight\"><strong>Weight<\/strong><\/td>\n<td title=\"42 kgs\">42 kgs<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;Features&#8221; tab_id=&#8221;1619955253927-f2fa3760-6480&#8243;][vc_column_text]<\/p>\n<ul>\n<li class=\"list_view\">Capacity : 105 L<\/li>\n<li class=\"list_view\">Direct cooling technology with manual defrost<\/li>\n<li class=\"list_view\">Baskets for organized sample storage<\/li>\n<li class=\"list_view\">Consistent performance during long-term refrigeration<\/li>\n<li class=\"list_view\">Digital control panel for temperature monitoring and alarms<\/li>\n<li class=\"list_view\">Latched door-lock for dependable sample protection<\/li>\n<\/ul>\n<p>[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;Application&#8221; tab_id=&#8221;1619955295151-d6e97e48-8c44&#8243;][vc_column_text]Used in diagnostic laboratories, clinical pathology laboratories for standardized storage for temperature sensitive specimen, enzyme, reagents, and other bio-chemical products used for research applications.[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;Optional Module&#8221; tab_id=&#8221;1624890466113-7383ac10-cd23&#8243;][vc_column_text]<\/p>\n<table class=\"tableizer-table\">\n<thead>\n<tr class=\"tableizer-firstrow\">\n<th>Module No.<\/th>\n<th>Module Name<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>ATR-10<\/td>\n<td>Thermal Recorder<\/td>\n<\/tr>\n<tr>\n<td>COB-10<\/td>\n<td>CO2 Backup system<\/td>\n<\/tr>\n<tr>\n<td>LNB-10<\/td>\n<td>LN2 Backup system<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>[\/vc_column_text][\/vc_tta_section][\/vc_tta_tabs][vc_separator color=&#8221;black&#8221;][\/vc_column][\/vc_row][vc_row css=&#8221;.vc_custom_1619893416459{margin-top: 100px !important;padding-bottom: 100px !important;}&#8221;][vc_column][vc_single_image image=&#8221;4461&#8243; img_size=&#8221;full&#8221; alignment=&#8221;center&#8221; lightbox=&#8221;yes&#8221; label=&#8221;&#8221;][vc_column_text]<\/p>\n<h2 class=\"product-title\" style=\"text-align: center;\" title=\"-86 \u00b0C ULT Chest freezer LB-21UCF\">-86 \u00b0C ULT Chest Freezer LB-21UCF<\/h2>\n<p style=\"text-align: center;\" title=\"-86 \u00b0C ULT Chest freezer LB-21UCF is a cold storage horizontal freezer equipped with electronic temperature control. Direct-cooling ensures consistent performance at utmost efficiency for prolonged refrigeration. Storage zone can be suitably organized for optimum space utilization to maximize sample occupancy. Temperature controller renders reliable temperature stability. System alarms include high or low set temperature limits, sensor fail, temperature controller fail and power-off conditions.\">-86 \u00b0C ULT Chest freezer LB-21UCF is a cold storage horizontal freezer equipped with electronic temperature control. Direct-cooling ensures consistent performance at utmost efficiency for prolonged refrigeration. Storage zone can be suitably organized for optimum space utilization to maximize sample occupancy. Temperature controller renders reliable temperature stability. System alarms include high or low set temperature limits, sensor fail, temperature controller fail and power-off conditions.<\/p>\n<p>[\/vc_column_text][vc_tta_tabs style=&#8221;modern&#8221; color=&#8221;white&#8221; alignment=&#8221;center&#8221; active_section=&#8221;1&#8243; css_animation=&#8221;fadeInUpBig&#8221; css=&#8221;.vc_custom_1619955735016{background-color: #ffffff !important;}&#8221;][vc_tta_section title=&#8221;Specification&#8221; tab_id=&#8221;1624940883309-60234368-eb2a&#8221;][vc_column_text]<\/p>\n<table class=\"table table-striped table-bordered displayshow1\">\n<tbody>\n<tr class=\"trset1\">\n<td title=\"Storage capacity\"><strong>Storage capacity<\/strong><\/td>\n<td title=\"188 L\">188 L<\/td>\n<\/tr>\n<tr class=\"trset1\">\n<td title=\"Baskets\"><strong>Baskets<\/strong><\/td>\n<td title=\"4\">4<\/td>\n<\/tr>\n<tr class=\"trset1\">\n<td title=\"External size\"><strong>External size<\/strong><\/td>\n<td title=\"1695 \u00d7 840 \u00d7 962 mm\">1695 \u00d7 840 \u00d7 962 mm<\/td>\n<\/tr>\n<tr class=\"trset1\">\n<td title=\"Internal size\"><strong>Internal size<\/strong><\/td>\n<td title=\"1456 \u00d7 526 \u00d7 674 mm\">1456 \u00d7 526 \u00d7 674 mm<\/td>\n<\/tr>\n<tr class=\"trset1\">\n<td title=\"Temperature range\"><strong>Temperature range<\/strong><\/td>\n<td title=\"-40 \u00b0C to -86 \u00b0C\">-40 \u00b0C to -86 \u00b0C<\/td>\n<\/tr>\n<tr class=\"trset1\">\n<td title=\"Temperature sensor\"><strong>Temperature sensor<\/strong><\/td>\n<td title=\"PTC\">PTC<\/td>\n<\/tr>\n<tr class=\"trset1\">\n<td title=\"Evaporator\"><strong>Evaporator<\/strong><\/td>\n<td title=\"Copper coiled tube\">Copper coiled tube<\/td>\n<\/tr>\n<tr class=\"trset1\">\n<td title=\"Condenser\"><strong>Condenser<\/strong><\/td>\n<td title=\"Tube type\">Tube type<\/td>\n<\/tr>\n<tr class=\"trset1\">\n<td title=\"Compressor\"><strong>Compressor<\/strong><\/td>\n<td title=\"1\">1<\/td>\n<\/tr>\n<tr class=\"trset1\">\n<td title=\"Refrigerant\"><strong>Refrigerant<\/strong><\/td>\n<td title=\"HFC\">HFC<\/td>\n<\/tr>\n<tr class=\"trset1\">\n<td title=\"No. of test holes\"><strong>No. of test holes<\/strong><\/td>\n<td title=\"1\">1<\/td>\n<\/tr>\n<tr class=\"trset1\">\n<td title=\"Diameter of test hole\"><strong>Diameter of test hole<\/strong><\/td>\n<td title=\"25 mm\">25 mm<\/td>\n<\/tr>\n<tr class=\"trset1\">\n<td title=\"Noise\"><strong>Noise<\/strong><\/td>\n<td title=\"54 dB\">54 dB<\/td>\n<\/tr>\n<tr class=\"trset1\">\n<td title=\"Power consumption\"><strong>Power consumption<\/strong><\/td>\n<td title=\"11.5 kWh\">11.5 kWh<\/td>\n<\/tr>\n<tr class=\"trset1\">\n<td title=\"Power supply\"><strong>Power supply<\/strong><\/td>\n<td title=\"220 V \/ 50 Hz ; 3.57 A\">220 V \/ 50 Hz ; 3.57 A<\/td>\n<\/tr>\n<tr class=\"trset1\">\n<td title=\"Power\"><strong>Power<\/strong><\/td>\n<td title=\"670 W\">670 W<\/td>\n<\/tr>\n<tr class=\"trset1\">\n<td title=\"Weight\"><strong>Weight<\/strong><\/td>\n<td title=\"130 kgs\">130 kgs<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;Features&#8221; tab_id=&#8221;1624940883398-beebee66-5cf6&#8243;][vc_column_text]<\/p>\n<ul>\n<li class=\"list_view\">Capacity : 485 L<\/li>\n<li class=\"list_view\">Direct cooling technology with manual defrost<\/li>\n<li class=\"list_view\">Baskets for organized sample storage<\/li>\n<li class=\"list_view\">Consistent performance during long-term refrigeration<\/li>\n<li class=\"list_view\">Digital control panel for temperature monitoring and alarms<\/li>\n<li class=\"list_view\">Latched door-lock for dependable sample protection<\/li>\n<\/ul>\n<p>[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;Application&#8221; tab_id=&#8221;1624940883489-901f454e-e21c&#8221;][vc_column_text]Used in diagnostic laboratories, clinical pathology laboratories for standardized storage for temperature sensitive specimen, enzyme, reagents, and other bio-chemical products used for research applications.[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;Optional Module&#8221; tab_id=&#8221;1624940883577-918c9a9e-25c2&#8243;][vc_column_text]<\/p>\n<table class=\"tableizer-table\">\n<thead>\n<tr class=\"tableizer-firstrow\">\n<th>Module No.<\/th>\n<th>Module Name<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>ATR-10<\/td>\n<td>Thermal Recorder<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>[\/vc_column_text][\/vc_tta_section][\/vc_tta_tabs][vc_separator color=&#8221;black&#8221;][\/vc_column][\/vc_row]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>[vc_row][vc_column][vc_cta h2=&#8221;-86 \u00b0C ULT Chest Freezer&#8221; style=&#8221;custom&#8221; add_button=&#8221;right&#8221; btn_title=&#8221;Get Quote&#8221; btn_style=&#8221;outline&#8221; btn_color=&#8221;white&#8221; btn_size=&#8221;lg&#8221; btn_skin=&#8221;light&#8221; btn_scale=&#8221;scale-2&#8243; btn_show_arrow=&#8221;yes&#8221; btn_btn_arrow=&#8221;yes&#8221; css_animation=&#8221;fadeInUpBig&#8221; custom_background=&#8221;#a561a9&#8243; custom_text=&#8221;#ffffff&#8221;][\/vc_cta][\/vc_column][\/vc_row][vc_row css=&#8221;.vc_custom_1619893416459{margin-top: 100px !important;padding-bottom: 100px !important;}&#8221;][vc_column][vc_single_image image=&#8221;4459&#8243; img_size=&#8221;full&#8221; alignment=&#8221;center&#8221; lightbox=&#8221;yes&#8221; label=&#8221;&#8221;][vc_column_text] -86 \u00b0C ULT Chest Freezer LB-20UCF -86 \u00b0C ULT Chest freezer LB-20UCF is a cold storage horizontal freezer equipped with electronic temperature control. Direct-cooling ensures [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":4459,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[113,10,2],"tags":[],"class_list":["post-4458","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-freezer","category-lab-equipment","category-laboratory"],"featured_image_src":{"landsacpe":["https:\/\/rehmantech.net\/demo\/bsscientifics\/wp-content\/uploads\/2021\/06\/86-C-ULT-Chest-freezer-LB-20UCF-250x250-1.jpg",250,250,false],"list":["https:\/\/rehmantech.net\/demo\/bsscientifics\/wp-content\/uploads\/2021\/06\/86-C-ULT-Chest-freezer-LB-20UCF-250x250-1.jpg",250,250,false],"medium":["https:\/\/rehmantech.net\/demo\/bsscientifics\/wp-content\/uploads\/2021\/06\/86-C-ULT-Chest-freezer-LB-20UCF-250x250-1.jpg",250,250,false],"full":["https:\/\/rehmantech.net\/demo\/bsscientifics\/wp-content\/uploads\/2021\/06\/86-C-ULT-Chest-freezer-LB-20UCF-250x250-1.jpg",250,250,false]},"_links":{"self":[{"href":"https:\/\/rehmantech.net\/demo\/bsscientifics\/wp-json\/wp\/v2\/posts\/4458","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/rehmantech.net\/demo\/bsscientifics\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/rehmantech.net\/demo\/bsscientifics\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/rehmantech.net\/demo\/bsscientifics\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/rehmantech.net\/demo\/bsscientifics\/wp-json\/wp\/v2\/comments?post=4458"}],"version-history":[{"count":1,"href":"https:\/\/rehmantech.net\/demo\/bsscientifics\/wp-json\/wp\/v2\/posts\/4458\/revisions"}],"predecessor-version":[{"id":4462,"href":"https:\/\/rehmantech.net\/demo\/bsscientifics\/wp-json\/wp\/v2\/posts\/4458\/revisions\/4462"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/rehmantech.net\/demo\/bsscientifics\/wp-json\/wp\/v2\/media\/4459"}],"wp:attachment":[{"href":"https:\/\/rehmantech.net\/demo\/bsscientifics\/wp-json\/wp\/v2\/media?parent=4458"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/rehmantech.net\/demo\/bsscientifics\/wp-json\/wp\/v2\/categories?post=4458"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/rehmantech.net\/demo\/bsscientifics\/wp-json\/wp\/v2\/tags?post=4458"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}