{"id":4486,"date":"2021-06-29T18:41:41","date_gmt":"2021-06-29T13:41:41","guid":{"rendered":"https:\/\/rehmantech.net\/demo\/bsscientifics\/?p=4486"},"modified":"2021-06-29T18:50:57","modified_gmt":"2021-06-29T13:50:57","slug":"automated-microtome","status":"publish","type":"post","link":"https:\/\/rehmantech.net\/demo\/bsscientifics\/laboratory\/automated-microtome\/","title":{"rendered":"Automated Microtome"},"content":{"rendered":"<p>[vc_row][vc_column][vc_cta h2=&#8221;Automated Microtome&#8221; style=&#8221;custom&#8221; add_button=&#8221;right&#8221; btn_title=&#8221;Get Quote&#8221; btn_style=&#8221;outline&#8221; btn_color=&#8221;white&#8221; btn_size=&#8221;lg&#8221; btn_skin=&#8221;light&#8221; btn_scale=&#8221;scale-2&#8243; btn_show_arrow=&#8221;yes&#8221; btn_btn_arrow=&#8221;yes&#8221; css_animation=&#8221;fadeInUpBig&#8221; custom_background=&#8221;#a561a9&#8243; custom_text=&#8221;#ffffff&#8221;][\/vc_cta][\/vc_column][\/vc_row][vc_row css=&#8221;.vc_custom_1619893416459{margin-top: 100px !important;padding-bottom: 100px !important;}&#8221;][vc_column][vc_single_image image=&#8221;4490&#8243; img_size=&#8221;full&#8221; alignment=&#8221;center&#8221; lightbox=&#8221;yes&#8221;][vc_column_text]<\/p>\n<h2 class=\"product-title\" style=\"text-align: center;\" title=\"Automated Microtome LB-30AM\">Automated Microtome LB-30AM<\/h2>\n<p style=\"text-align: center;\" title=\"Automated microtome LB-30AM is a bench-top unit with an adjustable specimen sectioning speed. Hand wheel lock is provided for user safety. Equipped with an overload protection function and an emergency brake system. Ideal for precise slicing of paraffin and hard specimens without harming the integrity of the specimen.\">Automated microtome LB-30AM is a bench-top unit with an adjustable specimen sectioning speed. Hand wheel lock is provided for user safety. Equipped with an overload protection function and an emergency brake system. Ideal for precise slicing of paraffin and hard specimens without harming the integrity of the specimen.<\/p>\n<p>[\/vc_column_text][vc_tta_tabs style=&#8221;modern&#8221; color=&#8221;white&#8221; alignment=&#8221;center&#8221; active_section=&#8221;1&#8243; css_animation=&#8221;fadeInUpBig&#8221; css=&#8221;.vc_custom_1619955735016{background-color: #ffffff !important;}&#8221;][vc_tta_section title=&#8221;Specification&#8221; tab_id=&#8221;1619955253898-53ec73a7-d134&#8243;][vc_column_text]<\/p>\n<table class=\"table table-striped table-bordered displayshow1\">\n<tbody>\n<tr class=\"trset1\">\n<td title=\"Section thickness range\"><strong>Section thickness range<\/strong><\/td>\n<td title=\"0.5 \u00b5m ~ 100 \u00b5m\">0.5 \u00b5m ~ 100 \u00b5m<\/td>\n<\/tr>\n<tr class=\"trset1\">\n<td title=\"Specimen retraction range\"><strong>Specimen retraction range<\/strong><\/td>\n<td title=\"20 \u00b5m\">20 \u00b5m<\/td>\n<\/tr>\n<tr class=\"trset1\">\n<td title=\"Vertical specimen stroke\"><strong>Vertical specimen stroke<\/strong><\/td>\n<td title=\"60 mm\">60 mm<\/td>\n<\/tr>\n<tr class=\"trset1\">\n<td title=\"Maximum specimen size\"><strong>Maximum specimen size<\/strong><\/td>\n<td title=\"50 mm \u00d7 50 mm\">50 mm \u00d7 50 mm<\/td>\n<\/tr>\n<tr class=\"trset1\">\n<td title=\"Object feed\"><strong>Object feed<\/strong><\/td>\n<td title=\"28 mm\">28 mm<\/td>\n<\/tr>\n<tr class=\"trset1\">\n<td title=\"Minimum setting value\"><strong>Minimum setting value<\/strong><\/td>\n<td title=\"0.5 \u00b5m\">0.5 \u00b5m<\/td>\n<\/tr>\n<tr class=\"trset1\">\n<td title=\"Precision error\"><strong>Precision error<\/strong><\/td>\n<td title=\"\u00b1 5 %\">\u00b1 5 %<\/td>\n<\/tr>\n<tr class=\"trset1\">\n<td title=\"Trimming thickness range\"><strong>Trimming thickness range<\/strong><\/td>\n<td style=\"font-family: Rambla, sans-serif !important; letter-spacing: 0px !important; box-sizing: border-box; color: #000000; padding: 8px; line-height: 1.42857; vertical-align: top; border: 1px solid #dddddd; text-align: center;\" title=\"1.0 \u00b5m ~ 600 \u00b5m&lt;hr&gt; 1.0 \u00b5m ~ 10 \u00b5m ( 1 \u00b5m increment )&lt;hr&gt; 10 \u00b5m ~ 20 \u00b5m ( 2 \u00b5m increment )&lt;hr&gt; 20 \u00b5m ~ 100 \u00b5m ( 10 \u00b5m increment )&lt;hr&gt; 100 \u00b5m ~ 600 \u00b5m ( 50 \u00b5m increment )\">\n<p style=\"text-align: left;\">1.0 \u00b5m ~ 600 \u00b5m<\/p>\n<hr \/>\n<p style=\"text-align: left;\">1.0 \u00b5m ~ 10 \u00b5m ( 1 \u00b5m increment )<\/p>\n<hr \/>\n<p style=\"text-align: left;\">10 \u00b5m ~ 20 \u00b5m ( 2 \u00b5m increment )<\/p>\n<hr \/>\n<p style=\"text-align: left;\">20 \u00b5m ~ 100 \u00b5m ( 10 \u00b5m increment )<\/p>\n<hr \/>\n<p style=\"text-align: left;\">100 \u00b5m ~ 600 \u00b5m ( 50 \u00b5m increment )<\/p>\n<\/td>\n<\/tr>\n<tr class=\"trset1\">\n<td title=\"Setting values\"><strong>Setting values<\/strong><\/td>\n<td style=\"font-family: Rambla, sans-serif !important; letter-spacing: 0px !important; box-sizing: border-box; color: #000000; padding: 8px; line-height: 1.42857; vertical-align: top; border: 1px solid #dddddd; text-align: center;\" title=\"0.5 \u00b5m ~ 2.0 \u00b5m ( 0.5 \u00b5m increment )&lt;hr&gt; 2.0 \u00b5m ~ 10 \u00b5m ( 1 \u00b5m increment )&lt;hr&gt; 10 \u00b5m ~ 20 \u00b5m ( 2 \u00b5m increment )&lt;hr&gt; 20 \u00b5m ~ 100 \u00b5m ( 5 \u00b5m increment )\">\n<p style=\"text-align: left;\">0.5 \u00b5m ~ 2.0 \u00b5m ( 0.5 \u00b5m increment )<\/p>\n<hr \/>\n<p style=\"text-align: left;\">2.0 \u00b5m ~ 10 \u00b5m ( 1 \u00b5m increment )<\/p>\n<hr \/>\n<p style=\"text-align: left;\">10 \u00b5m ~ 20 \u00b5m ( 2 \u00b5m increment )<\/p>\n<hr \/>\n<p style=\"text-align: left;\">20 \u00b5m ~ 100 \u00b5m ( 5 \u00b5m increment )<\/p>\n<\/td>\n<\/tr>\n<tr class=\"trset1\">\n<td style=\"text-align: left;\" title=\"Voltage\"><strong>Voltage<\/strong><\/td>\n<td style=\"font-family: Rambla, sans-serif !important; letter-spacing: 0px !important; box-sizing: border-box; color: #000000; padding: 8px; line-height: 1.42857; vertical-align: top; border: 1px solid #dddddd; text-align: center;\" title=\"AC 220 V ; 50 Hz&lt;hr&gt; AC 110 V ; 60 Hz\">\n<p style=\"text-align: left;\">AC 220 V ; 50 Hz<\/p>\n<hr \/>\n<p style=\"text-align: left;\">AC 110 V ; 60 Hz<\/p>\n<\/td>\n<\/tr>\n<tr class=\"trset1\">\n<td title=\"Power\"><strong>Power<\/strong><\/td>\n<td title=\"150 VA\">150 VA<\/td>\n<\/tr>\n<tr class=\"trset1\">\n<td title=\"Dimensions\"><strong>Dimensions<\/strong><\/td>\n<td title=\"580 \u00d7 330 \u00d7 310 mm\">580 \u00d7 330 \u00d7 310 mm<\/td>\n<\/tr>\n<tr class=\"trset1\">\n<td title=\"Weight\"><strong>Weight<\/strong><\/td>\n<td title=\"35 kgs\">35 kgs<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;Features&#8221; tab_id=&#8221;1619955253927-f2fa3760-6480&#8243;][vc_column_text]<\/p>\n<ul>\n<li class=\"list_view\">LCD screen displays number of sections and trimming thickness<\/li>\n<li class=\"list_view\">Manual \/ automatic sectioning mode<\/li>\n<li class=\"list_view\">Control panel with lock function for error free operation<\/li>\n<li class=\"list_view\">Single \/ continuous sectioning control<\/li>\n<li class=\"list_view\">Cassette clamp for embedded tissue sectioning<\/li>\n<li class=\"list_view\">standard specimen clamp for stability<\/li>\n<li class=\"list_view\">Overload and sleep mode protection function<\/li>\n<\/ul>\n<p>[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;Application&#8221; tab_id=&#8221;1619955295151-d6e97e48-8c44&#8243;][vc_column_text]Used in engineering, medicine, pathology, histology, botany laboratories, research institutes, etc.[\/vc_column_text][\/vc_tta_section][\/vc_tta_tabs][\/vc_column][\/vc_row]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>[vc_row][vc_column][vc_cta h2=&#8221;Automated Microtome&#8221; style=&#8221;custom&#8221; add_button=&#8221;right&#8221; btn_title=&#8221;Get Quote&#8221; btn_style=&#8221;outline&#8221; btn_color=&#8221;white&#8221; btn_size=&#8221;lg&#8221; btn_skin=&#8221;light&#8221; btn_scale=&#8221;scale-2&#8243; btn_show_arrow=&#8221;yes&#8221; btn_btn_arrow=&#8221;yes&#8221; css_animation=&#8221;fadeInUpBig&#8221; custom_background=&#8221;#a561a9&#8243; custom_text=&#8221;#ffffff&#8221;][\/vc_cta][\/vc_column][\/vc_row][vc_row css=&#8221;.vc_custom_1619893416459{margin-top: 100px !important;padding-bottom: 100px !important;}&#8221;][vc_column][vc_single_image image=&#8221;4490&#8243; img_size=&#8221;full&#8221; alignment=&#8221;center&#8221; lightbox=&#8221;yes&#8221;][vc_column_text] Automated Microtome LB-30AM Automated microtome LB-30AM is a bench-top unit with an adjustable specimen sectioning speed. Hand wheel lock is provided for user safety. Equipped with an overload protection [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":4490,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[113,10,2,115],"tags":[],"class_list":["post-4486","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-freezer","category-lab-equipment","category-laboratory","category-microtome"],"featured_image_src":{"landsacpe":["https:\/\/rehmantech.net\/demo\/bsscientifics\/wp-content\/uploads\/2021\/06\/Automated-Microtome-LB-30AM-250x250-1.jpg",250,250,false],"list":["https:\/\/rehmantech.net\/demo\/bsscientifics\/wp-content\/uploads\/2021\/06\/Automated-Microtome-LB-30AM-250x250-1.jpg",250,250,false],"medium":["https:\/\/rehmantech.net\/demo\/bsscientifics\/wp-content\/uploads\/2021\/06\/Automated-Microtome-LB-30AM-250x250-1.jpg",250,250,false],"full":["https:\/\/rehmantech.net\/demo\/bsscientifics\/wp-content\/uploads\/2021\/06\/Automated-Microtome-LB-30AM-250x250-1.jpg",250,250,false]},"_links":{"self":[{"href":"https:\/\/rehmantech.net\/demo\/bsscientifics\/wp-json\/wp\/v2\/posts\/4486","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/rehmantech.net\/demo\/bsscientifics\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/rehmantech.net\/demo\/bsscientifics\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/rehmantech.net\/demo\/bsscientifics\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/rehmantech.net\/demo\/bsscientifics\/wp-json\/wp\/v2\/comments?post=4486"}],"version-history":[{"count":6,"href":"https:\/\/rehmantech.net\/demo\/bsscientifics\/wp-json\/wp\/v2\/posts\/4486\/revisions"}],"predecessor-version":[{"id":4497,"href":"https:\/\/rehmantech.net\/demo\/bsscientifics\/wp-json\/wp\/v2\/posts\/4486\/revisions\/4497"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/rehmantech.net\/demo\/bsscientifics\/wp-json\/wp\/v2\/media\/4490"}],"wp:attachment":[{"href":"https:\/\/rehmantech.net\/demo\/bsscientifics\/wp-json\/wp\/v2\/media?parent=4486"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/rehmantech.net\/demo\/bsscientifics\/wp-json\/wp\/v2\/categories?post=4486"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/rehmantech.net\/demo\/bsscientifics\/wp-json\/wp\/v2\/tags?post=4486"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}